Never water, streaky. The low-voltage current transformer is a device that can convert high AC current into an easily controlled low-current device with excellent performance and stable accuracy. It is the most commonly used type of current transformer in the market today. Talking about this time ACCESS Electric Product Low voltage current transformer Selection problem. 1. Pre-customer requirements a. Determine the rating. b. Customers wear bronze or cable. c. Bronze size, number of roots ( I Type bronze medal can only 1 root, II , III According to the inner diameter, you can have more than one). d. Cable size, small change ratio can be accepted. e. Maximum case size. f. Installation method determined. 2. Transformer ratio determination a. Customer provides ratio specification, engineering department confirms feasibility, and determines the ratio if feasible. b. If the customer provides a ratio that cannot be completed, consult with the customer to increase the number of turns or reduce the level requirements. For larger ratios, discuss whether to choose a larger transformer. c. Customer provides CAD drawings for selection. If the selection is an integer such as: 200/5A Then select 200/5A . If it is a small variable ratio integer 40/5A After confirming with the customer 2 Hey. That is 40/5A ( 2 turns) If it is a small change than a non-integer 32/5A Optional after confirmation with the customer 40/5A ( 2 turns) If it is a big change than a non-integer 380/5A Optional type is 400/5A (only can be increased) d. In the selection, the inspection range of the factory transformer tester shall prevail, such as 315/5A The factory can be tested as an optional type, such as 1100/5A Even if the ratio is large, the factory inspection device cannot detect it and it is not optional. e. In the above situation, the customer has already calculated the short-time excess current. When the customer explicitly proposes that the current ratio is the direct measured current, the current selection should be larger than the measured current. Choosing a value around 2/3 of the rated current is more secure. f. The factory produces transformers that cannot exceed the operating current 1.1 times the rated current under normal operation, and up to 1.2 times for short periods. 3. Final model determination Based on the size and specifications of each sample transformer, the ratio is determined, and the customer confirms and submits it to the marketing department. For example, order: BH-0.66Φ30 Window rated current ratio: 200/5 Wear heart count: 1 turn rated output: 5VA Accuracy level: 0.5 Level installation method: A with D installation The order code is: ACH-0.66-30I-200/5 1 turn 5VA 0.5 level A+D installation Appendix: Selection of conventional transformer models (special models can be contacted by the engineering department) Keywords: signal indicator, push button switch, transformer, power meter, transfer switch Laser Instrument Shell Packaging Laser Instrument Shell Packaging,Gtms Enclosure With Gold Plating,Glass To Metal Sealed Enclosure With Gold Plate,Glass To Metal Sealed Enclosure Terminal Shenzhen Capitol Micro-Electronics Co.,LTD , https://www.capitolgtms.com
Transformer tester conventional model
1
75
2
80
3
90
4
100
5
120
6
125
7
150
8
200
9
250
10
300
11
315
12
350
13
400
14
450
15
500
16
600
17
700
18
800
19
900
20
1000
21
1200
22
1250
23
1400
24
1500
25
1600
26
1800
27
2000
28
2500
29
3000
30
3150
31
4000
32
5000